Sale!

Analytic Systems 2-Bank 40A AC Charger 24V Output 110V AC Input CSA/UL

$138

SKU: Analytic Systems 2-Bank 40A AC Charger 24V Output 110V AC Input CSA/UL
Category:

Analytic Systems 2-Bank 40A AC Charger 24V Output 110V AC Input CSA/UL Electrical

2 Bank 40A AC Charger, 24V Output, 110VAC Input CSA/UL

This BCA1000 COTS AC source battery charger is designed to charge a battery at 24V DC.

Internally, the single-board design incorporates proven switching mode technology for unmatched efficiency and ultra-quiet operation. Additional stages of filtering. on the outputs reduce conducted and radiated EMI noise to very low levels.

This unit features a user selectable 2 or 3 stage charging profile, and the output voltage adjusts for optimal charging. Additionally, equalization mode and voltage temperature compensation increase the life of expensive battery systems.

Built for rugged use, this unit is built. Made from heavy duty anodized extruded billet aluminum with O-rings and all stainless steel fastenersThe.

Reliability features of this product line include LED status indicators, overheat shutdown, current limiting, reverse polarity battery, full connection protection, shutdown output short circuit protection with automatic recovery and output overvoltage protection.

Features:

  • Adjustable charging voltage
  • Single or dual pad charging
  • Ultra-quiet, low EMI operation
  • Bright LED indicators
  • Equalizer mode functionality
  • Robust and reliable

Specifications:

Input:

  • Rated voltage: 110 VAC
  • Actual voltage: 90-133 VAC
  • Frequency: 45-65
  • Input amps (maximum): 13 A
  • Input fuse (slow blow): MDA-20

Output:

  • Nominal voltage: 24 VDC
  • Floating voltage : 27.2 VDC
  • Absorption voltage: 28.8 VDC
  • Load amps: 40 A
  • Output fuses (parallel): 2x ATC - 30
  • Sinking to float switch: 6 A
  • Output overvoltage protection: 32 ± 1 V
  • Temperature compensation: -60 mV/°C
  • Equalization voltage: 31.0 VDC
  • Recommended Completed battery size (amp-hours): 160-240
  • Number supported. of Battery Banks: Charges up to two connected battery banks
  • Output Volt. Adjust: +/- 1.0 V
  • Charging stages (selectable): 2 stages (CC-Float) or 3 stages (CC-Absorption-Float), user selectable
  • Output Ripple & Noise: <50 mV
  • Transient Response: <1 V for 50% overvoltage
  • Regulation (line and load): <+/- 0 .5%
  • Service Cycle: Continuous (100% for 24 hours per day)
  • Efficiency:>75% at maximum output

Mechanics:

  • Length: 14.5 in / 36.8 cm
  • Width: 9.9 in / 25.1 cm
  • Height: 5.0 in / 12.7 cm
  • Clearance: 1.0 in / 2.5 cm all around
  • Weight: 12. 0 lb / 5.5 kg (approximately)
  • Material and finish: Black anodized marine grade aluminum
  • Fasteners: 18-8 stainless steel
  • Connection Input: 3m / 9.8ft 3xAWG14 power cord with NEMA 5-15 or CEE 7/VII compatible plug
  • Output Connection: 4-pin Molex BEAU terminal Strip
  • >Battery temperature sensor connection: RJ45 "phone jack" connector

Environment and safety:

  • Battery temperature operation: -25°C to +40°C at maximum output. Linear derating of 2.5% per °C from +40°C
  • Storage temperature: -40°C to +100°C
  • Humidity: 0 to 95% relative humidity (non-condensing) with standard conforming covering
  • Insulation: entre-output and input box: 1500 VDC; Output box: 500 VDC (1500 VDC at 48 V output)
  • Cooling: Two interior thermostatic cooling fans
  • Audible noise: 0 dB at 1 meter when fan is operating
  • Typical life:> 10 years (87,600 hours)
  • Warranty: Three years on parts and labor
  • Safety: engineered to meet UL458 and CSA 22.2.107.1 standards
This product cannot be returned to the original point of purchase. Please contact the manufacturer directly with any problems or concerns.


PRODUCT ID: 104279
SKU: NVN-104279
CSKU: CWR-104279
REWRITE : 115390-analytic-systems-ac-charger-2-bank-40a-24v
MPN: BCA1000-110-24
UPC:
ASIN:
WSKU:
SSKU:
KSKU:
GSKU:
MSKU:
LSKU:
NAME: ANALYTICAL SYSTEMS AC CHARGER 2-BANK 40A 24V OUTPUT 110VAC IN
EX_NAME:
PTITLE: AC ChargerAnalytical Systems Kit 2 Banks 40 A, 24 V Output, 110 V AC Input CSA/UL
TYPE: Electric | Battery Chargers
SELLER: Analytic Systems
VEHICLES & PARTS> VEHICLE PARTS & ACCESSORIES> WATERCRAFT PARTS & ACCESSORIES




Gtags:

GSpecs:

Analytic Systems 2 Bank 40 Amp AC Charger, 24 V Output, 110 V AC Input CSA/UL Product Description

2 Bank 40 Amp AC Charger, 24 V Output, 110 V AC Input CSA/UL

This BCA1000 COTS AC source battery charger is designed to charge a battery at 24V DC.

Internally, single board design incorporates proven switching mode technology for unmatched efficiency. and ultra-quiet operation. Additional stages of filtering on the outputs reduce conducted and radiated EMI noise to very low levels.

This unit features a user-selectable 2 or 3 stage charging profile, and the Output voltage adjusts for optimal charging. . Additionally, equalization mode and voltage temperature compensation increase the life of expensive battery systems.

Built for rugged use, this unit is constructed from extruded aluminumHeavy-duty anodized and machined from billet with O-rings and all stainless steel fasteners.

Reliability features of this product line include LED status indicators, overheat shutdown, power limitation current, reverse polarity battery connection protection, output short circuit shutdown with automatic recovery and output overvoltage protection.

Features:

  • Adjustable charging voltage
  • Charging on one or two banks
  • Ultra quiet, low EMI operation
  • Bright LED indicators
  • Equalizer mode functionality
  • Robust and reliable

Specifications:

Input :

  • Rated voltage: 110 VAC
  • Actual voltage: 90-133 VAC
  • Frequency: 45-65
  • Input Amps (Maximum): 13 A
  • Input Fuse (Slow Blow): MDA-20

Output:

  • Rated voltage: 24 VDC
  • Floating voltage: 27.2 VDC
  • Absorption voltage: 28.8 VDC
  • Load current: 40 A
  • Output fuses (parallel): 2x ATC-30
  • Sinking to float switch: 6 A
  • Output overvoltage protection: 32 ± 1 V
  • Temperature compensation: -60 mV/°C
  • Equalization voltage: 31 .0 VDC
  • Recommended battery size (amp-hours): 160-240
  • Supported number. of Battery Banks: Charges up to two connected battery banks
  • Output Volt. Adjust: +/- 1.0 V
  • Charging stages (selectable): 2 stages (CC-Float) or 3 stages (CC-Absorption-Float), user selectable
  • Output Ripple & Noise: <50 mV
  • Transient Response: <1 V for 50% overvoltage
  • Regulation (line and load): <+/- 0 .5%
  • Service Cycle: Continuous (100% duringt 24 hours per day)
  • Efficiency:>75% at maximum output

Mechanical:

  • Length: 14.5 in / 36.8 cm
  • Width: 9.9 in / 25.1 cm
  • Height: 5.0 in / 12.7 cm
  • Clearance: 1.0 in / 2.5 cm all around
  • Weight: 12.0 lb / 5.5 kg (approx.)
  • Material and finish : Black anodized marine grade aluminum
  • Mountings: 18-8 stainless steel
  • Input connection: 3 m / 9.8 ft 3xAWG14 in. Power cord with NEMA 5 compatible plug -15 or CEE 7/VII
  • Output connection: 4-pin Molex BEAU terminal block
  • Battery temperature sensor connection: RJ45 "telephone jack" connector

Environment and safety:

  • Operating temperature: -25°C to +40°C at maximum output. Linear derating of 2.5% per °C from +40°C
  • Storage temperature: -40°C to +100°C
  • Humidity: 0 to 95% relative humidity(non-condensing) with standard conformal coating
  • Isolation: input-output and input box: 1500 VDC; Output box: 500 VDC (1500 VDC at 48 V output)
  • Cooling: Two interior thermostatic cooling fans
  • Audible noise: 0 dB at 1 meter when fan is operating
  • Typical life:> 10 years (87,600 hours)
  • Warranty: Three years on parts and labor
  • Safety: engineered to meet UL458 and CSA 22.2.107.1 standards
This product cannot be returned to the original point of purchase. Please contact the manufacturerectly with any issues or concerns.



Save $177 when you purchase the Analytic Systems 2 AC Charger 40A Banks, 24V Output, 110V AC in CSA/ULfor only $1,179 from NVN Marine! Free same day delivery before 3 p.m. Analytic Systems AC charger 2 banks 40 A, outlet24V tie, 110V AC input CSA/UL Technical Specifications
Type:

Electric | Battery Chargers

Supplier:

Analysis Systems

Charging banks:

2

Product brochure:

Download PDF

Analytic Systems 2 Bank 40A AC Charger, 24V Output, 110V AC Input User Reviews CSA/ULAnalytic Systems AC Charger 2 banks 40 A, 24 V output, 110 V AC In CSA/UL Shipping and Return

For detailed shipping policy, please see our Shipping Policy and you will find our Return and Refund policy here.