Maretron 0-3 PSI Submersible Pressure Transducer Marine Navigation & Instruments
0-3 PSI Submersible Pressure Transducer
Maretron submersible pressure transducers indicate tank levels and can be installed directly in the tank. Please follow these instructions to mount and connect a submersible pressure transducer to a NMEA 2000 network via a Maretron FPM100 fluid pressure monitor. Maretron recommends one of two methods for mounting a submersible pressure transducer in a tank: 1) without a retaining tube and 2) with a retaining tube.
Submersible pressure transducers are designed for tank with a 5-hole SAE J1810 at the top. Install the mounting plate with strain relief onto the transducer cable, with the rounded hexagonal section of the strain relief facing away from the transducer.
Lower the pressure transducer into the tank so that that it is at the lowest point. of the tank and tighten the cable clamp tor fix the cable. On a flat bottom tank, the transducer may slide from side to side with the movement of the vessel but will not rotate due to the stiffness of the cable. It is also possible to mount the pressure transducer inside a retaining or focusing tube (sold separately, reference Maretron TFT-5H).
Mounting the pressure transducer
Connect the two pressure transducer wires to a free pressure monitoring channel. Connect the red wire from the pressure transducer to the positive (+) channel terminal and connect the black wire from the pressure transducer to the negative (-) channel terminal. The example in Figure 1 shows the pressure transducer connected to switching channel 0, with the white wire connected to "P0+" and the brown wire connected to "P0-". Submersible pressure transducers have a small plastic vent tube in the connection cable.
Use a serial screenie Maretron DSM (firmware 1.4.7 or higher) or a PC running Maretron N2KAnalyzer software (version 1.4.19 or higher). to configure the connected channel(s) on the FPM100.
Power Supply power to the NMEA 2000 network and verify that the pressure channel indicates a valid pressure reading.
Specifications:
- Operating range: 0 to 3 PSI (0.207 bar)
- Depth range (water): 83.1" (2.11 m)
- Diesel depth range (820 kg/m3): 101.3" (2.57 m)
- Gasoline/Petrol depth range (750 kg) /m3): 110.8" (2.81 m)
- Cable Length: 17 ft (5.18 m)
- Sensor Type: Gauge (Vent Tube)
- Output: 4 - 20 mA current loop, loop powered
- Excitation voltage: 8 VDC to 28 VDC
- Compatible fluids/gases: Diesel , Diesel Exhaust Fluid (DEF), Gasoline/Gasoline, Hydraulic Fluid, Kerosene, Engine Oil, Fresh Water, Sea Water, Waste Water
- TemOperating Temperature: 14 degrees F to 158 degrees F (-10 degrees C to 80 degrees C)
- Storage Temperature: -4 degrees F to 176 degrees F (-20 degrees C to 80 degrees C)
- Accuracy: ±0.3% typ. at 25°C
- Total error band (TEB): ±1.0% typ. (-10 degrees C to 70 degrees C)
- Nonlinearity, hysteresis (NLH): ±0.2% typ. Best Straight Line (BSL) at 25°C
- Temperature compensation: 23 degrees F to 122 degrees F (0 degrees C to 50 degrees C)
- Accuracy: ±1% of full scale
- Linearity: 0.5% of full scale
- Repeatability: 0.05% of full scale
- Thermal error at full scale: 0.04% of full scale/°F (0.07% of full scale/degrees C)
- Long term stability: 0.2% full scale/year
- Response time: 150 ms
- Proof pressure: 2 × full scale
- li>
- Burst pressure: 3 × full scale
- Reverse voltage protection: ±30 V for 3 minutes
- Construction: 316L stainless steel body and diaphragm, polyether polyurethane cable, chloroprene sheath
- EMC compatibility: 10 Volts/meter according to EN 61000-4-3
- Weight: 24.8 oz (703 g)
PRODUCT ID: 102517
SKU: NVN-102517
CSKU : CWR-102517
REWRITE: 113628-maretron-submersible-pressure-transducer-0-3-psi
MPN: PTS-0 -3PSI-02
UPC: 873804004556
ASIN:
WSKU:
SSKU:
KSKU: MRTPTS03PSI02
GSKU:
MSKU:
LSKU:
NAME: MARETRON SUBMERSIBLE PRESSURE TRANSDUCER 0 TO 3 PSI
NAME_EX:
PTITLE: Maretron 0-3 PSI Submersible Pressure Transducer
TYPE: Navigation & Marine Instruments | NMEA Cables and Sensors
SELLER: Maretron
ELECTRONICS> MARINE ELECTRONICS> Marine Chartplotters and GPS
Amazon Category :
Gtags:
GSpecs:
Maretron 0-3 PSI Submersible Pressure Transducer Product Description
0-3 PSI Submersible Pressure Transducer
Maretron submersible pressure transducers indicate tank levels and can be installed directly in the tank. Please follow these instructions to mount and connect a submersible pressure transducer to a NMEA 2000 network via a Maretron FPM100 fluid pressure monitor. Maretron recommends one of two methods for mounting a submersible pressure transducer in a tank: 1) without a retaining tube and 2) with a retaining tube.
Submersible pressure transducers are designed for tank with a 5-hole SAE J1810 at the top. Install the mounting plate with strain relief onto the transducer cable, with the rounded hexagonal section of the strain relief facing away from the transducer.
Lower the pressure transducer into the tank so that that heis at the lowest point. of the tank and tighten the cable clamp to secure the cable. On a tank with a bottom, the transducer may slide from side to side with the movement of the vessel but will not rotate due to the stiffness of the cable. It is also possible to mount the pressure transducer inside a retaining or focusing tube (sold separately, reference Maretron TFT-5H).
Mounting the pressure transducer
Connect the two pressure transducer wires to a free pressure monitoring channel. Connect the red wire from the pressure transducer to the positive (+) channel terminal and connect the black wire from the pressure transducer to the negative (-) channel terminal. The example in Figure 1 shows the pressure transducer connected to switching channel 0, with the white wire connected to "P0+" and the brown wire connected to "P0-". Submersible pressure transducers have a small vent tube inplastic in the connection cable.
Use a Maretron DSM series display (firmware 1.4.7 or higher) or a PC running Maretron N2KAnalyzer software (version 1.4.19 or higher). to configure the connected channel(s) on the FPM100.
Power the NMEA 2000 network and verify that the pressure channel indicates a valid pressure reading.
Specifications:
- Operating range: 0 to 3 PSI (0.207 bar)
- Depth range (water): 83.1" (2.11 m)
- Depth range Diesel (820 kg/m3): 101.3 inches (2.57 m)
- Depth range gasoline/gasoline (750 kg /m3): 110.8 inches (2.81 m)
- Cable length: 17 feet (5.18 m)
- Sensor type: Gauge (vent tube)
- Output: 4 - 20 mA current loop, loop powered
- Excitation voltage: 8 VDC to 28 VDC
- Compatible fluids/gases: diesel, diesel exhaust fluid (DEF), gasoline/gasoline, fluidhydraulic, kerosene, engine oil, fresh water, sea water, waste water
- Operating temperature: 14 degrees F to 158 degrees F (-10 degrees C to 80 degrees C)
- Storage temperature: -4 degrees F to 176 degrees F (-20 degrees C to 80 degrees C)
- Accuracy: ±0.3% typ. at 25°C
- Total error band (TEB): ±1.0%, typ. full scale. (-10 degrees C to 70 degrees C)
- Nonlinearity, hysteresis (NLH): ±0.2% typ. Best Straight Line (BSL) at 25°C
- Temperature compensation: 23 degrees F to 122 degrees F (0 degrees C to 50 degrees C)
- Accuracy: ±1% of full scale
- Linearity: 0.5% of full scale
- Repeatability: 0.05% of full scale
- Thermal error at full scale: 0.04% of full scale/°F (0.07% of full scale/degrees C)
- Long term stability: 0.2% full scale/year
- Response time: 150 ms
- Proof pressure: 2 × full scale
- li>
- PBurst voltage: 3 × full scale
- Reverse voltage protection: ± 30 V for 3 minutes
- Construction: 316L stainless steel body and diaphragm, polyurethane polyether cable , chloroprene sheath
- EMC compatibility: 10 Volts/meter according to EN 61000-4-3
- Weight: 24.8 oz (703 g)
Save $59 when you purchase the Maretron 0-3 PSI Submersible Pressure Transducer for 350 $from NVN Marine! Same day dispatch before 3 p.m. Maretron 0-3 PSI Submersible Pressure Transducer Technical Specifications
Type: | Marine Navigation & Instruments | NMEA Cables and Sensors |
---|---|
Supplier: | Maretron |
Weight: | 1.35 lbs |
Product Manual: | Download PDF |
Shipping Weight: | 1.35 lb |
---|---|
Box sizes: | 1.00 (h) x 10.00 (w) x 11.00 (l) |
Cubic feet: | 110.0 |
Returnable: | Yes |
For detailed shipping terms, please view our shipping policy and you can find our return and refund policy here.
- Maretron Submersible Pressure Transducer - 0-1.5 PSI
- Maretron Submersible Pressure Transducer - 0 to 5 PSI
- Maretron Submersible Pressure Transducer - 0 to 3 PSI
- Maretron Submersible Pressure Transducer - 0 to 1.5 PSI
- Maretron Replacement Impeller Kit
- Maretron cable-free gyro/solid-state compass
- Maretron Solid State Gyro Compass with 10m Cable and Connector