Victron Lynx Smart BMS 1000 battery management system for smart lithium batteries Electrical

Lynx Smart BMS 1000 battery management system for lithium smart batteries

The Lynx Smart BMS is a battery management system (BMS) dedicated to Victron smart batteries Lithium Battery. These batteries are Lithium Iron Phosphate (LiFePO4) batteries and are available in 12.8 V or 25.6 V in different capacities. They can be connected in series, parallel and series/parallel so that a battery bank can be built for system voltages of 12V, 24V or 48V. The maximum number of batteries in a system is 20, which gives a maximum of batteries. energy storage of 84 kWh in a 12 V system and up to 102 kWh in a 24 V1) and 48 V1) system.

Among the different BMS available, the Lynx Smart BMS is the richest in functionality and complete option and integrates perfectly into the Lynx distribution system. This model is a 1000 A version (M10).

1000 A in contactortegr

The contactor acts as a secondary safety system to protect the battery. in case the main control tools (ATC, ATD and/or DVCC) fail to deactivate the loads and/or chargers when necessary and are also suitable as the main switch of the remotely controllable system.

Precharge circuit

In addition to the contactor, an integrated precharge circuit prevents high inrush currents when connecting a capacitive load such as a MultiPlus/ Quattro or other inverter, eliminating the need for external precharging.

Monitoring and Control

Monitor and control the BMS via Bluetooth using the VictronConnect app or a GX device such as a Cerbo GX and VRM portal. A built-in battery monitor that functions similarly to other Victron Energy battery monitors, provides data such as battery statusarge, voltage, current, historical data, status information, etc. in real time and with instant playback, even without the need to do so. connect to the BMS, allowing at-a-glance diagnosis.

DVCC closed loop control as well as ATC/ATD contacts

Victronles compatible Inverters/chargers and solar chargers are automatically controlled via a connected GX device and DVCC. ATC/ATD contacts can be used to control other chargers and loads that have a remote on/off port.

Programmable Relay

The relay can be used either as an alarm relay (associated with the pre-alarm) or to control an alternator via its external regulator (ignition cable). In ATC Alternator mode, the relay will only activate when the contactor is closed. Alternator The ATC contact of the alternator opens first, then with a delay of 2 seconds the contactor. These 2seconds ensure that the alternator is turned off before the battery is disconnected from the system.

AUX terminal

The advantage of on-board auxiliary power (1.1 A at system voltage) is intended to power specific loads (i.e. a GX device) after the BMS has shut down the loads in the event of a low cell voltage event. If no charging voltage is detected within 5 minutes, the BMS including the AUX connection will turn off.

VE.Can and NMEA 2000 data communication

VE.Can allows easy connection (standard RJ45 network cable) and communication with a GX device. As the CANbus protocol is based on NMEA 2000 (and J1939), it is easy to integrate into a marine network and feed data to a marine MFD (requires VE.Can micro-C male cable to NMEA 2000).

Lynx Distributor Fuse Monitoring

Read fuse status and receive an alarm in cace of grilling. The Lynx Smart BMS monitors up to 4 connected Lynx distributors and their fuses via VictronConnect or a GX device. 1) To reduce the balancing time required, we recommend using as many different batteries in series as possible for the application. 24V systems are best built using 24V batteries and a 48V system.

This system contains the following components:

  • Lynx distributor with 2 parallel fused lithium-ion batteries smart batteries.
  • Lynx Smart BMS with BMS, contactor and battery monitor
  • A second Lynx distributor provides fused connections for the inverters /chargers, loads and chargers (additional modules can be added if more connections are required)
  • A Cerbo GX (or other GX device) to read data from the Lynx Smart BMS and Lynx Distributor.

Food specificationsation:

  • Battery voltage range: 9 to 60 VDC
  • Maximum input voltage: 75 VDC
  • Voltage Supported system voltage: 12, 24 or 48 V
  • Reverse polarity protection: No
  • Continuous current rating of main safety contactor: 1000 A continuous
  • Main safety contactor peak current rating: 1200 A for 5 minutes
  • OFF mode power consumption: 0.3 mA for all system voltages
  • Power consumption in standby mode: approx. 0.6 W (50 mA at 12 V)
  • Power consumption in ON mode: approx. 2.6 W (217 mA at 12 V) depending on the state of the relays
  • Approximately 4.2 W (350 mA at 12 V) depending on the state of the relays
  • Resistance of minimum load for precharge: 10 Ω and above for 12 V systems, 20 Ω and above for 24 V and 48 V systems
  • Maximum AUX output current rating: 1.1 A continuous, protected by a resettable fuse
  • Maximum charge permit port current rating: 0.5 A at 60 V DC, protected by a resettable fuse
  • Maximum discharge permit port current rating: 0.5 A at 60 VDC, protected by a resettable fuse
  • Alarm relay (SPDT) Maximum current rating: 2 A at 60 VDC

Connections:

  • Busbar: M10 (Torque: 17 Nm)
  • VE.Can: RJ45
  • I/O: removable multi-connector with screw terminals
  • Battery BTV cables: 3-pole circular male and female connector with M8 screw ring Up to 20 batteries can be connected in a Lynx system Distributor fuse monitoring (up to 4 modules ) RJ10 (cable supplied with each Lynx distributor)

Physical specifications:

  • Housing material: ABS
  • Housing dimensions (h x w x d): 230 x 180 x 100 mm
  • Unit weight: 2.7 kg
  • Busbar material: Coppertin-plated
  • Busbar dimensions (h x w): 8 x 30 mm

Environmental specifications:

  • Operating temperature range: -40°C to +60°C
  • Storage temperature range: -40°C to +60°C
  • Max. humidity. : 95% (non-condensing)
  • Protection class: IP22

Standards

  • Safety: EN-IEC 63000:2018
  • EMC: EN-IEC 61000-6-3:2007/A1:2011/AC:2012
  • QMS: NEN-EN-ISO 9001:2015
Please contact your dealer for any return, repair, or support issues related to this product.


PRODUCT ID: 101855
SKU: NVN-101855
CSKU: CWR- 101855
REWRITE: 112966-victron-lynx-smart-bms-1000-battery-management
MPN: LYN034170210
UPC:
ASIN :
WSKU:
SSKU:
KSKU:
GSKU:
MSKU:
LSKU:
NAME: VICTRON LYNX SMART BMS 1000 MSYSTEM 10 MGMT F/LITHIUM
NAME_EX:
PTITLE: Management systemVictron Lynx Smart BMS 1000 battery station for smart lithium batteries
TYPE: Electric | Battery Management
SELLER: Victron Energy
VEHICLES & PARTS> VEHICLE PARTS & ACCESSORIES> WATERCRAFT PARTS & ACCESSORIES




Gtags:

GSpecs:

Victron Lynx Smart BMS 1000 Battery Management System for Lithium Smart Batteries Product Description

Lynx Smart BMS 1000 Battery Management System for Lithium Smart Batteries

The Lynx Smart BMS is a dedicated Battery Management System (BMS) for Victron Lithium Battery Smart batteries. These batteries are Lithium Iron Phosphate (LiFePO4) batteries and are available in 12.8 V or 25.6 V in different capacities. They can be connected in series, parallel and series/parallel so that a battery bank can be built for system voltages of 12V, 24V or 48V. The maximum number of batteries in a system is 20, which gives a maximum of batteries. energy storage of 84 kWh in a 12 V system and up to 102 kWh in a 24 V1) and 48 V1) system.

Among the different BMS available, the Lynx Smart BMS is the richest in features and complete option and integratesperfectly in the Lynx distribution system. This model is a 1000 A version (M10).

Integrated 1000 A contactor

The contactor acts as a secondary safety system to protect the battery in case the main controls (ATC, ATD and/or DVCC) fail to deactivate the loads and/or chargers when required and is also suitable as a remotely controllable main contactor. system switch.

Precharge circuit

In addition to the contactor, a built-in precharge circuit prevents high inrush currents when connecting a a capacitive contactor. load such as a MultiPlus/Quattro or other inverter, eliminating the need for external precharging.

Monitoring and Control

Monitor and control the BMS via Bluetooth using the VictronConnect app or a GX device such as a Cerbo GX and the VRM portal. A built-in battery monitorD which works the same as other Victron Energy battery monitors, provides data such as state of charge, voltage, current, historical data, status information, etc. in real time and with instant playback, even without the need to do so. Connect to the BMS, allowing at-a-glance diagnosis.

DVCC closed loop control as well as ATC/ATD contacts

Inverters Compatible Victron chargers and solar chargers are automatically controlled via a connected GX device and DVCC. ATC/ATD contacts can be used to control other chargers and loads that have a remote on/off port.

Programmable Relay

The relay can be used either as an alarm relay (associated with the pre-alarm) or to control an alternator via its external regulator (ignition cable). In ATC Alternator mode, the relay will only activate when the coswitch is closed. Alternator The ATC contact of the alternator opens first, then with a delay of 2 seconds the contactor. These 2 seconds ensure that the alternator is turned off before the battery is disconnected from the system.

AUX terminal

The power advantage On-board auxiliary (1.1 A at system voltage) is used to power specific loads (i.e. a GX device) after the BMS is closed.wn the loads in the event of a low cell voltage event . If no charging voltage is detected within 5 minutes, the BMS including AUX connection will turn off.

VE.Can and NMEA 2000 data communication

VE. .Can allows easy connection (standard RJ45 network cable) and communication with a GX device. As the CANbus protocol is based on NMEA 2000 (and J1939), it is easy to integrate into a marine network and feed data to a marine MFD (requires a VE.Can male micro-C cable toNMEA 2000).

Lynx distributor fuse monitoring

Read fuse status and receive an alarm if blown. The Lynx Smart BMS monitors up to 4 connected Lynx distributors and their fuses via VictronConnect or a GX device. 1) To reduce the balancing time required, we recommend using as many different batteries in series as possible for the application. 24V systems are best built using 24V batteries and a 48V system.

This system containsIncludes the following components:

  • Lynx distributor with 2 lithium-ion smart batteries fused in parallel.
  • Lynx Smart BMS with BMS, contactor and battery monitor
  • A second Lynx distributor provides fused connections for the inverters /chargers, charges and chargers (additional modules can be added if more connections are needed)
  • A Cerbo GX (or other GX device) to read data from the Lynx Smart BMS and Lynx distributor.

Power specifications:

  • Battery voltage range: 9 – 60 VDC
  • Maximum input voltage: 75 VDC
  • Supported system voltage: 12, 24 or 48 V
  • Reverse polarity protection: No
  • Continuous current rating of main safety contactor: 1000 A continuous
  • Peak current rating of contactor main safety voltage: 1200 A for 5 minutes
  • Power consumption in OFF mode: 0.3 mA for all system voltages
  • Power consumption in standby mode: approximately 0 .6 W (50 mA at 12 V)
  • Power consumption in ONMode: approx. 2.6 W (217 mA at 12 V) depending on relay status
  • Approximately 4.2 W (350 mA at 12 V) depending on relay status
  • Resistance minimum load for precharging: 10 Ω and above for 12 V systems, 20 Ω and abovefor 24V and 48V systems
  • Maximum AUX output current rating: 1.1A continuous, protected by resettable fuse
  • Maximum charging authorization port current rating : 0.5 A at 60 V DC, protected by a resettable fuse.
  • Maximum current rating of the discharge authorization port: 0.5 A at 60 V DC, protected by a resettable fuse. fuse
  • Alarm relay (SPDT) Maximum current: 2 A at 60 VDC

Connections:

  • Busbar: M10 (Torque: 17 Nm)
  • VE.Can: RJ45
  • I/O: Removable multi-connector with screw terminals
  • Battery BTV Cables: 3-pole circular male and female connector with M8 screw ring Up to 20 batteries can be connected in a system Lynx distributor fuse monitoring (up to 4 modules) RJ10 (ca(ble supplied with each Lynx distributor )

Physical Specifications:

  • Case Material:ABS
  • Enclosure Dimensions (h x w x d): 230 x 180 x 100 mm
  • Unit weight: 2.7 kg
  • Busbar material: Tinned copper
  • Busbar dimensions (h x w): 8 x 30 mm

Environmental specifications:

  • Operating temperature range: -40°C to +60°C
  • Storage temperature range: -40°C to +60°C
  • Maximum humidity: 95% (non-condensing)
  • Protection class: IP22

Standards

  • Safety: EN -IEC 63000:2018
  • EMC: EN-IEC 61000-6-3: 2007/A1:2011/AC:2012
  • QMS: NEN-EN-ISO 9001:2015
Please contact your dealer for any returns, repairs, or support issues related to this product.



Save $220 when you purchase the Victron Lynx Smart BMS 1000 f/Lithium Smart Batteries Battery Management System for only $1,249 from NVNMarin! Delivery gfree the same day before 3 p.m. Victron Lynx Smart BMS 1000 Battery Management System for Lithium Smart Batteries Technical Specifications
Type:

Electric | Battery management

Supplier:

Victron Energy

User Guide:

Download PDF

Product Manual:

Download PDF

Victron Lynx Smart BMS 1000 Battery Management System for Lithium Smart Batteries User ReviewsBattery Management System Victron Lynx Smart BMS 1000 for Lithium Smart Batteries Shipping & Return

For detailed shipping terms, please see our shipping policy and you can find our return & refund policy here.